• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Ana Sayfa
  • Tıp Fakültesi
  • Dahili Tıp Bilimleri Bölümü
  • Dahili Tıp Bilimleri Bölümü Tez Koleksiyonu
  • Öğe Göster
  •   Ana Sayfa
  • Tıp Fakültesi
  • Dahili Tıp Bilimleri Bölümü
  • Dahili Tıp Bilimleri Bölümü Tez Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Orta Geçirgen Diyaliz Membranı İle Diyalize Giren Hastaların Kan İnflamatuvar Belirteç Düzeylerinin Ve Arteriyal Kompliyanslarının Değerlendirilmesi

Göster/Aç
İrem OZARLI tez 2021 .pdf (1.509Mb)
Tarih
2021
Yazar
Ozarlı, İrem
Ambargo Süresi
Acik erisim
Üst veri
Tüm öğe kaydını göster
Özet
Cardiovascular diseases are the main cause of morbidity and mortality in patients with end-stage renal disease undergoing hemodialysis. Although significant advances have been made in hemodialysis treatment, survival and quality of life have improved compared to the past, the results are still unsatisfactory. Medium cut-off dialysis membranes are one of the new treatment approaches in the hemodialysis process, which are developed to ensure the removal of medium molecular weight uremic toxins that cannot be removed from the body with standard dialysis membranes and play a role in the development of various uremic complications. In this study, the effects of medium cut-off dialysis membranes on inflammatory markers in the blood, cardiac function and arterial stiffness were investigated by comparing the patients undergoing dialysis with medium cut-off and standard dialysis membranes at Hacettepe University Nephrology Department Hemodialysis Unit. A total of 50 patients, 25 patients for both groups, were included in the study. In the group undergoing dialysis with a medium cut-off dialysis membrane, β-2 microglobulin levels (p<0.01), a medium molecular weight uremic toxin, and serum CRP (p<0.001), Interleukin-18 (p<0.05) and Pentraxin-3 (p<0.01) levels were found to be significantly lower. In addition, pulse wave velocity (p<0.01) and augmentation index (p<0.05) values, which are indicators of arterial stiffness, were found to be significantly lower in patients undergoing dialysis with a medium-permeable dialysis membrane. This difference in arterial stiffness markers may be related to the suppression of inflammation by the medium cut-off membranes and the improvement of endothelial functions. In conclusion, when compared with standard dialysis membranes, moderately permeable dialysis membranes may provide an advantage in long-term cardiovascular morbidity and mortality in hemodialysis patients due to their anti-inflammatory effects.
 
Cardiovascular diseases are the main cause of morbidity and mortality in patients with end-stage renal disease undergoing hemodialysis. Although significant advances have been made in hemodialysis treatment, survival and quality of life have improved compared to the past, the results are still unsatisfactory. Medium cut-off dialysis membranes are one of the new treatment approaches in the hemodialysis process, which are developed to ensure the removal of medium molecular weight uremic toxins that cannot be removed from the body with standard dialysis membranes and play a role in the development of various uremic complications. In this study, the effects of medium cut-off dialysis membranes on inflammatory markers in the blood, cardiac function and arterial stiffness were investigated by comparing the patients undergoing dialysis with medium cut-off and standard dialysis membranes at Hacettepe University Nephrology Department Hemodialysis Unit. A total of 50 patients, 25 patients for both groups, were included in the study. In the group undergoing dialysis with a medium cut-off dialysis membrane, β-2 microglobulin levels (p<0.01), a medium molecular weight uremic toxin, and serum CRP (p<0.001), Interleukin-18 (p<0.05) and Pentraxin-3 (p<0.01) levels were found to be significantly lower. In addition, pulse wave velocity (p<0.01) and augmentation index (p<0.05) values, which are indicators of arterial stiffness, were found to be significantly lower in patients undergoing dialysis with a medium-permeable dialysis membrane. This difference in arterial stiffness markers may be related to the suppression of inflammation by the medium cut-off membranes and the improvement of endothelial functions. In conclusion, when compared with standard dialysis membranes, moderately permeable dialysis membranes may provide an advantage in long-term cardiovascular morbidity and mortality in hemodialysis patients due to their anti-inflammatory effects.
 
Bağlantı
http://hdl.handle.net/11655/25991
Koleksiyonlar
  • Dahili Tıp Bilimleri Bölümü Tez Koleksiyonu [637]
Künye
Vancouver
Hacettepe Üniversitesi Kütüphaneleri
Açık Erişim Birimi
Beytepe Kütüphanesi | Tel: (90 - 312) 297 6585-117 || Sağlık Bilimleri Kütüphanesi | Tel: (90 - 312) 305 1067
Bizi Takip Edebilirsiniz: Facebook | Twitter | Youtube | Instagram
Web sayfası:www.library.hacettepe.edu.tr | E-posta:openaccess@hacettepe.edu.tr
Sayfanın çıktısını almak için lütfen tıklayınız.
İletişim | Geri Bildirim



DSpace software copyright © 2002-2016  DuraSpace
Theme by 
Atmire NV
 

 


DSpace@Hacettepe
huk openaire onayı
by OpenAIRE

Hakkımızda
Açık Erişim PolitikasıVeri Giriş RehberleriÜyeliklerİletişim

livechat

sherpa/romeo

Göz at

Tüm Açık ArşivBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreDile GöreErişim Şekline GöreDizinleme Kaynağına GöreFonlayan Kuruma GöreAlt Türe GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreDile GöreErişim Şekline GöreDizinleme Kaynağına GöreFonlayan Kuruma GöreAlt Türe Göre

Hesabım

GirişKayıt

İstatistikler

Kullanım İstatistiklerini Göster

DSpace software copyright © 2002-2016  DuraSpace
Theme by 
Atmire NV