• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   Ana Sayfa
  • Tıp Fakültesi
  • Dahili Tıp Bilimleri Bölümü
  • Dahili Tıp Bilimleri Bölümü Makale Koleksiyonu
  • Öğe Göster
  •   Ana Sayfa
  • Tıp Fakültesi
  • Dahili Tıp Bilimleri Bölümü
  • Dahili Tıp Bilimleri Bölümü Makale Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Diagnostic Accuracy of 16- Versus 64-Slice Multidetector Computed Tomography Angiography In The Evaluation of Coronary Artery Bypass Grafts: A Comparative Study

Göster/Aç
licence.txt (265bytes)
ivs335.pdf (226.1Kb)
Tarih
2012
Yazar
Şahiner, Levent
Canpolat, Uğur
Aytemir, Kudret
Hazirolan, Tuncay
Yorgun, Hikmet
Kaya, Ergun Baris
Oto, Ali
Üst veri
Tüm öğe kaydını göster
Özet
OBJECTIVES: Multidetector computed tomography (MDCT) angiography, which is used for native coronary vessels and bypass graft (CABG) imaging is a non-invasive test. Here, we aimed to compare the diagnostic accuracy of 16- and 64-slice MDCT for graft patency and stenosis. METHODS: A total of 129 consecutive patients with CABG who underwent both MDCT (58 patients with 16-slice, 71 patients with 64-slice) and invasive angiography were included. Median time interval between the two procedures was 12 days (range 3-28 days). Bypass grafts were evaluated concerning patency and presence of stenosis >= 50%. Both 16- and 64-slice MDCT results were compared with invasive angiography. RESULTS: Overall diagnostic accuracy for the detection of graft patency was 95% for 64-slice vs 92% for 16-slice MDCT. By analyzing the 173 grafts by 64-slice vs 153 grafts by 16-slice MDCT that could be evaluated, sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) of the MDCT for visualization of graft patency were 90, 98, 90 and 98% vs 87, 97, 94 and 93%, respectively. The accuracy of MDCT for the detection of significant graft stenosis was relatively low (sensitivity, specificity, PPV and NPV were 67, 98.6, 50 and 98.6% with 16-slice vs 80, 98.1, 72.7 and 98.7% with 64-slice). CONCLUSIONS: This study showed that the 16-slice has a diagnostic accuracy comparable with the 64-slice system for graft patency and can still be used for this purpose if newer systems with improved performance are not available on-site. On the other hand, by the virtue of better image quality, the 64-slice MDCT demonstrates significant graft lesions with higher sensitivity.
Bağlantı
https://doi.org/10.1093/icvts/ivs335
http://hdl.handle.net/11655/15506
Koleksiyonlar
  • Dahili Tıp Bilimleri Bölümü Makale Koleksiyonu [2912]
Hacettepe Üniversitesi Kütüphaneleri
Açık Erişim Birimi
Beytepe Kütüphanesi | Tel: (90 - 312) 297 6585-117 || Sağlık Bilimleri Kütüphanesi | Tel: (90 - 312) 305 1067
Bizi Takip Edebilirsiniz: Facebook | Twitter | Youtube | Instagram
Web sayfası:www.library.hacettepe.edu.tr | E-posta:openaccess@hacettepe.edu.tr
Sayfanın çıktısını almak için lütfen tıklayınız.
İletişim | Geri Bildirim



DSpace software copyright © 2002-2016  DuraSpace
Theme by 
Atmire NV
 

 


DSpace@Hacettepe
huk openaire onayı
by OpenAIRE

Hakkımızda
Açık Erişim PolitikasıVeri Giriş RehberleriÜyeliklerİletişim

livechat

sherpa/romeo

Göz at

Tüm Açık ArşivBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreDile GöreErişim Şekline GöreDizinleme Kaynağına GöreFonlayan Kuruma GöreAlt Türe GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreBölüme GöreYayıncıya GöreDile GöreErişim Şekline GöreDizinleme Kaynağına GöreFonlayan Kuruma GöreAlt Türe Göre

Hesabım

GirişKayıt

İstatistikler

Kullanım İstatistiklerini Göster

DSpace software copyright © 2002-2016  DuraSpace
Theme by 
Atmire NV